Boiler Not Heating the House? What Could Be Wrong
If your boiler isn’t heating the house, the trouble is almost always somewhere in the hot-water loop. Low pressure is one of the most common reasons. After that, it’s usually the circulator pump, a zone valve, air in the lines, or water that just isn’t getting hot enough.
You can narrow it down quite a bit before anyone shows up. It takes a look at the gauge on the front of the boiler and a quick walk through the house to see which rooms are cold. If you’d rather go straight to a technician, our boiler repair team can help, and if the house is losing heat fast, our emergency HVAC service line picks up 24/7.
Is the Whole House Cold or Just One Area?
Start with that walk through the house. If every room is cold, look at the boiler and the main pump, since those serve the whole system. If it’s just the upstairs, or just the addition over the garage, and that area has its own thermostat, you’re probably looking at a zone problem and not a boiler problem. And if one radiator is cold while the one across the room is hot, it’s almost always air or a closed valve at that radiator, which is a separate issue from the boiler itself.
It also helps to notice which floor gives out first. When the top floor goes cold, and the basement is still comfortable, the water usually isn’t making it all the way up. That points to low pressure or air.
What Your Boiler Gauge Is Telling You
Most hot-water boilers have a round gauge on the front, or on the pipe just above it. It shows pressure and water temperature at the same time, and it’s honestly the best clue you’ve got. (Technicians sometimes call it a tridicator.)
With the system cold, most homes sit somewhere around 12 to 15 psi, and the needle climbs a little once the boiler has been running. If it’s down near 5 in a two-story house, there probably isn’t enough pressure to push water to the second floor. On the other end, if it’s creeping toward 30, where the relief valve usually opens, the expansion tank is the likely culprit.
If the gauge says the water is hot, but the pipe a few feet away is barely warm, the water isn’t moving. If the gauge stays lukewarm even though the thermostat has been calling for an hour, the boiler isn’t heating the way it should, or it’s set too low.
Common Causes of a Boiler Not Heating the House
Low Water Pressure
Your heating loop is sealed, so water doesn’t just disappear. If the pressure keeps falling, it’s going somewhere. The usual spots are a relief valve that’s been weeping, a fitting with a slow drip, or an air vent that’s letting out water along with the air. A lot of systems also have an automatic fill valve that’s supposed to keep the pressure up, and when it clogs, the pressure slips a little more each week.
Topping off the system can get the upstairs warm again. It doesn’t fix anything if the water keeps leaving, though, so we look for the leak and check the fill valve before calling it done.
A Failed Circulator Pump
The circulator is a small pump, usually right next to the boiler, and its only job is pushing hot water out to the house and back. When it quits, the boiler keeps heating the same water and shutting off at its temperature limit, and the rest of the house never sees any of that heat. You might hear the pump humming without spinning, which usually means it’s seized. Or you might hear nothing at all.
A bad circulator generally gets replaced, not repaired. If yours is old, it’s worth asking about a variable-speed pump. It adjusts to how many zones are calling for heat and uses a lot less electricity than older pumps.
A Zone Valve or Zone Pump That Won’t Open
If your house has more than one thermostat, each one either opens a valve or turns on a pump for its part of the house. Zone valves have a little motor on top. When that motor burns out, the valve stays shut, and that zone gets nothing. The flip side happens too. A valve stuck open will keep heating a zone even with its thermostat turned all the way down.
The good news is that the motor head can usually be swapped without cutting into the piping. We’ll still check the thermostat and its wiring first, because a dead thermostat and a dead zone valve look exactly the same from the hallway.
Air Trapped in the Pipes
Air sneaks in whenever the system gets refilled, or the pressure runs low. It rises to the high spots in the piping and blocks the water from getting through, and it sounds like gurgling or water rushing inside the walls. Bleeding the radiators lets it out. If you find yourself bleeding them every couple of weeks, though, something is letting air in, and it’s usually low pressure or a vent or air separator that’s stopped doing its job.
A Waterlogged Expansion Tank
Hot water takes up more room than cold water, and the expansion tank is where that extra goes. Inside, there’s a cushion of air. Once that air is gone, the pressure jumps every time the boiler fires, and the relief valve dumps some water to protect the system. Later, when everything cools off, you’re short on water, and the pipes have air in them. A gauge that swings a lot between cold and hot is the giveaway. So is a puddle under the relief valve’s drain pipe. Sometimes the tank just needs its air charge restored, and sometimes it needs to be replaced.
Hot Water Priority on an Indirect Water Heater
Some boilers also make your household hot water, using a separate tank called an indirect water heater. Those systems are often set up so the tank comes first. After a few showers back to back, or laundry and the dishwasher running at once, the boiler stops sending heat to the radiators until the tank catches up. A short lukewarm spell after a busy morning is normal. If the house goes cold for hours at a time, the tank’s control might be stuck calling for heat, or the boiler might be too small to keep up with both.
Boiler Water Temperature Set Too Low
Newer boilers often have an outdoor sensor that turns the water temperature down on mild days and back up when it gets cold. It saves gas, and it’s why your radiators might feel warm instead of hot in October. The catch is that if the settings aren’t right for your house, the water never gets hot enough in January. On an older boiler, it can be as simple as a temperature dial that got turned down. Either way, it’s an adjustment, not a new part.
A Boiler Safety Lockout
If the burner won’t light at all, check the display for a code or a blinking light. Boilers shut themselves down when one of their safeties trips. That could be the low-water cutoff, the high limit, or the flame sensor after a few failed tries at lighting. One reset, following the steps on the boiler’s label, is fine. If it locks out again, don’t keep resetting it, because whichever safety tripped is pointing right at the problem. And if the display is completely blank, check the boiler’s service switch and breaker before anything else.
When to Call for Boiler Repair
Give us a call if the pressure won’t hold steady, the relief valve is dripping, the pump hums but nothing moves, a zone won’t heat, or the boiler locks out more than once. Pressure and air problems don’t fix themselves, and they tend to get worse as the season goes on. On a really cold night, a boiler that’s sitting idle can also leave the baseboard pipes along outside walls at risk of freezing.
The diagnostic is $75, or $99 on evenings, weekends, and holidays, and you’ll see a flat-rate price before we start any work.
Boiler Repair in Streamwood and the Northwest Suburbs
Pure Comfort Heating and Cooling is a family-owned company that’s served Streamwood and the northwest suburbs since 2008, and our technicians work on hot-water boilers, radiators, and baseboard heat all winter long. Call (708) 515-4822 any time, day or night.